products
- home
- Products
FHL-VACTM Flat Insulation Panel
FHL-VAC
TM Flat Insulation Panels are the thermal
resistance panels which helps to resist thermal radiations to reach the
furnace casing/body.
We manufacture the following product in various size and grade to meet our
customer needs.
Specifications of Standard Boards:
• Standard Density (Kg/m3): 200-240
• Standard Thickness: 50mm , 75mm Panels
• Standard L x W: 950 x 450 mm
Custom Built Board Dimensions:
• Standard Density (Kg/m3): 200-240
• L x W: 950 x 950mm per Board
• Thickness: 90, 100, 125mm
• We also work for your exacting requirements
Application:
• Chamber Furnace
• Continuous Furnace

Technical Data of FHL-VACTM Vacuum Formed Ceramic Fiber Modules & Panels
Parameter | FHL-M 1150 | FHL-Z 1325 | FHL- HT 1550 |
---|---|---|---|
Classification Temp (°C) | 1260 | 1425 | 1650 |
Max. Continuous Working Temp. (°C) | 1150 | 1325 | 1550 |
Density Range (Kg/m3) | 200-240 | 200-240 | 200-240 |
Linear Shrinkage (%) (24 Hour Continuous Working Temp.) | 1< | 1< | 1< |
Thermal Conductivity (W/mK)
Parameter | FHL-M 1150 | FHL-Z 1325 | FHL- HT 1550 |
---|---|---|---|
At 200°C | 0.065 | 0.065 | 0.065 |
At 600°C | 0.13 | 0.13 | 0.14 |
At 1000°C | 0.27 | 0.28 | 0.24 |
At 1200°C | 0.40 | 0.38 | 0.33 |
At 1300°C | 0.48 | 0.47 | 0.39 |
At 1400°C | - | 0.53 | 0.45 |
At 1500°C | - | - | 0.51 |
At 1600°C | - | - | - |
Chemical Composition (%)
Parameter | FHL-M 1150 | FHL-Z 1325 | FHL- HT 1550 |
---|---|---|---|
Al2O3 | 47 | 37.5 | 66 |
SiO2 | 53 | 49.5 | 33 |
Zr | - | 13 | - |